Dry Type Air Cooling 3 Phase Transformer

LUGAO's Dry Type Air Cooling 3 Phase Transformer are designed for efficient power distribution in various industries. Instead of using oil as a cooling medium, the transformer uses air, eliminating the possibility of oil leakage. It is insulated with high-quality epoxy resin and has good moisture and heat resistance. The use of high-quality materials and innovative design can effectively reduce energy loss and improve energy utilization. LUGAO's Dry Type Air Cooling 3 Phase Transformer meet international safety standards and protect modern power distribution networks.

LUGAO's Dry Type Air Cooling 3 Phase Transformer adopts industry-leading technology design to protect the power distribution network in various fields. As a leading transformer manufacturer and supplier in the industry, LUGAO of China provides professional power distribution solutions to customers around the world with sincere prices and considerate services

LUGAO Dry Type Air Cooling 3 Phase Transformer Introduction

LUGAO's Dry Type Air Cooling 3 Phase Transformer does not use oil as a cooling medium, but uses air, which greatly improves safety and reduces environmental impact. The transformer uses high-quality epoxy resin insulation material, has good fire resistance and self-extinguishing properties, and is suitable for use in places with high safety requirements.

 

LUGAO's Dry Type Air Cooling 3 Phase Transformer adopts an innovative design to ensure stable voltage regulation and can effectively reduce energy loss, which is essential to maintaining the efficiency of modern power systems. Its sturdy structure and easy installation characteristics can be flexibly installed in environments with limited space. China LUGAO's Dry Type Air Cooling 3 Phase Transformer meets strict international standards and protects modern power distribution networks.

 LUGAO Dry Type Air Cooling 3 Phase Transformer Parameter

Rated
capacity
(KVA)
HV LV Vector
Group
No-load
current
(%)
No-load
loss (W)
Load loss (W) Impedance
(%)
130℃(B) 150℃(F) 180℃(H)
30 6.3
10
11
0.4 dyn11
Yyno
Dyn5
2 190 670 710 760 4.5
50 2 270 940 1000 1070
80 1.5 370 1290 1380 1480
100 1.5 400 1480 1570 1690
125 1.3 470 1740 1850 1980
160 1.3 540 2000 2130 2280
200 1.1 620 2370 2530 2710
250 1.1 720 2590 2760 2960
315 1.0 880 3270 3470 3730
400 1.0 980 3750 3990 4280
500 1.0 1160 4590 4880 5230
630 0.85 1340 5530 5880 6290 6.0
800 0.85 1520 6550 6960 7460
1000 0.85 1770 7650 8130 8760
1250 0.85 2090 9100 9690 10300
1600 0.85 2450 11000 11700 12500 8.0
2000 0.7 3050 13600 14400 15500
2500 0.7 3600 16100 17100 18400

Dry Type Air Cooling 3 Phase Transformer

LUGAO Dry Type Air Cooling 3 Phase Transformer Operating Environment

1.The height above the sea level is below 1000m.

2.Highest air temperature +40ºC

3.Highest daily average air temperature +30ºC

4.Highest annual average air temperature+20v

5.Lowest outdoor air temperature-25ºC

6. Installation location: suitable for installation in areas free from fire or explosion hazards, significant pollution, chemical corrosion, or excessive vibration, whether indoors or outdoors.

LUGAO Dry Type Air Cooling 3 Phase Transformer Characteristics

1.Operate within specified limits: +40ºC (highest air temperature), +30ºC (highest daily average), and +20ºC (highest annual average).

2.Suitable for Dry type transformers at altitudes below 1000m. Consider extremes: -25ºC (lowest outdoor temperature).

Ventilation:

3.Adequate airflow is essential for Dry type transformers to dissipate heat.

4.Dry type transformers are resistant to moisture; protect from prolonged exposure to high humidity.

5.Dry type transformers should operate within specified load and voltage limits.

6.Implement protection measures against harmonics and voltage fluctuations.

7.Install Dry type transformers in areas free from fire/explosion hazards, pollution, corrosion, or excessive vibration, whether indoors or outdoors.

8.Adhere to regular maintenance practices per the manufacturer's recommendations.

9.Dry type transformers should operate within their specified overload capacity.

10.Maintain low noise levels in Dry type transformers.

Our Factory

Dry Type Air Cooling 3 Phase TransformerDry Type Air Cooling 3 Phase Transformer

Transportation

Dry Type Air Cooling 3 Phase Transformer

Hot Tags: Dry Type Air Cooling 3 Phase Transformer, China, Manufacturer, Supplier, Factory
Send Inquiry
Contact Info
If you have any enquiry about quotation or cooperation, please feel free to email or use the following inquiry form. Our sales representative will contact you within 24 hours.
X
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy
Reject Accept