Lugao Power Co., Ltd transformers have been successful in many countries in Central Asia and Africa, selling more than 100 units per year to foreign countries for use in substations, power plants, etc. Minimum order for 35kv On Load Regulator Transformer is 1 unit, which can be completed within 2 weeks. LUGAO also has Distribution Transformer in stock to respond to customer needs in a timely manner.
Lugao Power Co., Ltd.'s 35kV On Load Regulator Transformer utilizes the principle of electromagnetic induction for voltage conversion and employs transformer oil as the cooling medium. Lugao utilizes raw materials such as silicon steel sheets and windings to ensure superior material quality, reliable performance, and extended service life. LUGAO's 35kV Power Transformer has passed multiple international testing standards, ensuring product quality. Suitable for various power applications
Lugao Power Co., Ltd.'s Oil-Immersed Transformer excels in both performance and energy efficiency. The transformer is equipped with an on-load tap changer that can adjust the voltage in real time, ensuring stable output voltage. High-quality materials ensure the efficiency of the Amorphous Alloy Transformer, continuously reducing load and no-load losses while lowering maintenance costs. During the operation of the Online Tap Changer Transformer, the transformer oil used transfers the heat generated by the windings and core to the radiator, releasing the heat into the air through convection to prevent local overheating. The insulating oil also prevents direct contact between air and the core, avoiding oxidation of internal components and significantly extending the transformer's service life. Safety is paramount in urban operations, and LUGAO will implement transformer status visualization on the top of the Oltc Transformer, allowing you to monitor temperature, oil level, and other operational conditions at any time.
Parameter
Capacit y
GB/20052-2020
impedance voltage
(%)
no-load
current
(%)
Vector Group
Exten d
Conne
ction
(S13)
no-load loss
load loss
Dyn11/Yzn1 1
Yyno
30
65
455
430
4.0
0.5
Yyn0
OR
Dyn11
±2*2.
5%
OR±5
%
50
80
655
625
0.5
63
90
785
745
0.5
80
105
945
900
0.45
100
120
1140
1080
0.45
125
135
1360
1295
0.45
160
160
1665
1585
0.4
200
190
1970
1870
0.4
250
230
2300
2195
0.4
315
270
2760
2630
0.35
400
330
3250
3095
0.35
500
385
3900
3710
0.3
630
460
4460
4.5
0.25
800
560
5400
0.18
1000
665
7415
0.17
1250
780
8640
0.17
1600
940
10440
0.16
2000
1085
13180
5.0
0.16
2500
1280
13360
0.16
Operating Environment
1. Standard operating temperature: -30°C to +40°C. When the temperature exceeds 40°C, the unit must be operated in load-reduction mode.
2. Standard operating altitude: Below 1,000 meters.
3. Standard operating humidity: Daily average ≤95%, monthly average ≤90%.
4. When installing, ensure the tilt angle does not exceed 15°.
5. Regularly inspect the oil level gauge, oil quality, and surrounding environment.
6. Keep the 35kV On-Load Regulator Transformer away from flammable areas, electromagnetic interference zones, and other locations that may affect transformer operation.
Characteristics
1. The 35kV On Load Regulator Transformer has good heat dissipation performance. The transformer oil can quickly absorb heat from the windings and core and achieve heat circulation through the radiator.
2. Strong insulation capacity. The insulating oil can effectively isolate internal discharges.
3. Long service life. The transformer oil can protect the core and windings and slow down oxidation.
4. Strong environmental adaptability. The sealed oil tank can block external impurities.