Products
Fully Sealed Oil Immersed Transformer
  • Fully Sealed Oil Immersed TransformerFully Sealed Oil Immersed Transformer
  • Fully Sealed Oil Immersed TransformerFully Sealed Oil Immersed Transformer
  • Fully Sealed Oil Immersed TransformerFully Sealed Oil Immersed Transformer

Fully Sealed Oil Immersed Transformer

Model:S11-M
Lugao Power Co., Ltd. has achieved success in transformer projects in multiple countries, earning the trust of every customer through affordable prices and professional services. LUGAO boasts a highly professional team that is fully committed to serving customers, whether in technical matters or communication. This Fully Sealed Oil Immersed Transformer is ideal for customers with high environmental requirements.


The S11-M fully sealed oil-immersed transformer features an all-sealed structure, with the oil tank completely enclosed to ensure that the insulating oil is completely isolated from the air, thereby preventing oxidation of internal components. Even in high-humidity, dusty environments, the fully sealed oil-immersed transformer can operate stably without any adverse effects. It features a corrugated oil tank with a pressure relief valve for pressure release. Thanks to the high thermal capacity of the insulating oil, the transformer's overload capacity is enhanced. During arc breakdown at high temperatures, the insulating oil generates arc-quenching gases that can quickly extinguish the arc, preventing faults.


Thanks to the advantages of oil-immersed cooling, the fully sealed oil-immersed transformer can use a smaller core cross-section, thereby reducing no-load losses. Under the protection of insulating oil, the aging rate of internal components is slowed down, extending their service life. During installation, distribution transformers must maintain spacing to facilitate heat dissipation and should be kept away from densely populated areas. Before shipment, we perform vacuum oil filling and sealing to prevent leaks during transportation and facilitate installation.


Parameter

S11-M Fully Sealed Oil Immersed Transformer

Model Rated
Capacity
Voltage Group Connection
Symbol
No-load
Loss
Load Loss
75℃
No-load
Current
Short
Circuit
Impedanc
Weight Dimension
L*W*H
EH
High
Voltage
Low
Voltage
(KVA) (KV) (KV) - (W) (W) (A) (%) (KG) (MM) (MM)
S11-30/10 30 10 0.4 Yyn0/Dyn11 100 630 0.8 4.0 400 1050*63*1040 400*400
S11-50/10 50 130 910 0.7 460 1020*680*1080
S11-63/10 63 150 1090 0.6 500 1060*690*1090
S11-80/10 80 180 1310 0.5 550 1070*700*1100
S11-100/10 100 200 1580 0.5 620 1090*710*1120
S11-125/10 125 240 1890 0.45 700 1130*730*1180
S11-160/10 160 280 2310 0.42 830 1160*750*1180 550*550
S11-200/10 200 340 2730 0.4 910 1190*750*1260
S11-250/10 250 400 3200 0.4 1000 1230*770*1280
S11-315/10 315 480 3830 0.35 1430 1280*830*1290
S11-400/10 400 570 4520 0.35 1430 1310*830*1340 660*660
S11-500/10 500 680 5410 0.33 1600 1389*890*1380
S11-630/10 630 810 6200 0.28 1830 1490*980*1410
S11-800/10 800 980 7500 0.25 4.5 2300 1560*1000*1560 820*820
S11-1000/10 1000 1150 10300 0.25 2700 1700*1130*1650
S11-1250/10 1250 1360 12000 0.25 3200 1830*1230*1710
S11-1600/10 1600 1640 14500 0.23 3700 1880*1270*1790
S11-2000/10 2000 1960 18300 0.23 5.5 4500 1980*1310*1900 920*920
S11-2500/10 2500 2310 20700 0.23 5500 2360*1580*2300


Operating Environment

1. Standard operating temperature: -30°C to +40°C. When the temperature exceeds 40°C, the unit must be operated in load-reduction mode.

2. Standard operating altitude: Below 1,000 meters.

3. Standard operating humidity: Daily average ≤95%, monthly average ≤90%.

4. When installing, ensure the tilt angle does not exceed 15°.

5. Regularly inspect the oil level gauge, oil quality, and surrounding environment.

6. Keep the Fully Sealed Oil Immersed Transformer away from flammable areas, electromagnetic interference zones, and other locations that may affect transformer operation.

Characteristics

1. Lugao Power Co., Ltd's Fully Sealed Oil Immersed Transformer has good heat dissipation performance. The transformer oil can quickly absorb heat from the windings and core and achieve heat circulation through the radiator.

2. Strong insulation capacity. The insulating oil can effectively isolate internal discharges.

3. Long service life. The transformer oil can protect the core and windings and slow down oxidation.

4. Strong environmental adaptability. The sealed oil tank can block external impurities.

5.LUGAO professionally controls quality inspection to ensure that every detail is handled properly.


Our Factory

S11-M Fully Sealed Oil Immersed TransformerS11-M Fully Sealed Oil Immersed Transformer

Transportation

S11-M Fully Sealed Oil Immersed Transformer

Hot Tags: Fully Sealed Oil Immersed Transformer
Send Inquiry
Contact Info
If you have any enquiry about quotation or cooperation, please feel free to email or use the following inquiry form. Our sales representative will contact you within 24 hours.
X
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy
Reject Accept